Modern z/OS installations can be complex with many potential bottlenecks. This case study shows how IntelliMagic Vision may be used to easily find the root cause of a z/OS performance issue related to overloaded back-end drives. In fact, regular usage of IntelliMagic Vision can help you completely avoid issues like the one described here. Watch this case study and see how IntelliMagic Vision can deliver concrete benefits to your z/OS shop.

Video Transcript

In this video I’m going to demonstrate how IntelliMagic Vision may be used to isolate and resolve a performance problem in a large z/OS environment.

In this case the problem was reoccurring during a specific overnight time period. Many critical applications were suffering due to the slow down. We will show you how Vision was used to determine root cause and help define a concrete action plan.

Users were complaining about application slow downs during the overnight batch time period. Looking at the Disk during that period, we see elevated but not peak response times.

Next, we look at throughput along with response time and notice a spike in the total MB/sec at the same time as the elevated response time.

Splitting this out by Disk Storage System we notice that one particular unit stands out in terms of the response time peak.

The IntelliMagic Vision Dashboard clearly flags this storage system as having backend disk drive response time issues. It also points out that the throughput for this storage system is at a warning level. In fact if the dashboard had been regularly scanned, it is likely this problem could have been avoided altogether.

Drilling down from the dashboard, we see that the drive read response times are very high during the same time frame as the problem. Thus, it is likely that some of the drives are overloaded.

Drilling down to the storage pools we see that two of the six pools on this storage system are performing poorly. The other pools are all healthy.

Drilling down to the RAID arrays on one of the pools we find that the pool has only 4 RAID arrays in it. Possible solutions include adding more arrays to the pool or upgrading to faster disks or SSDs.

By looking at the back-end activity on the storage pools, we notice that during the problem time the write activity is highly increased on the problematic pools.

On the application side we can isolate the increase in back-end write load to just two LCUs. Rebalancing the workload is another option to resolve the problem.

This case study illustrates how IntelliMagic Vision made it easy to resolve this problem in a fast and efficient manner. As a result, further application slow downs would be avoided and staff would be free to work on other pressing matters.

If you would like to find out more about IntelliMagic Vision for your environment, please email us at info@intellimagic.com

Related Resources

News

What's New with IntelliMagic Vision for z/OS? 2024.2

February 26, 2024 | This month we've introduced changes to the presentation of Db2, CICS, and MQ variables from rates to counts, updates to Key Processor Configuration, and the inclusion of new report sets for CICS Transaction Event Counts.

Read more
Webinar

A Mainframe Roundtable: The SYSPROGS | IntelliMagic zAcademy

Discover the vital role of SYSPROGs in the mainframe world. Join industry experts in a concise webinar for insights and strategies in system programming.

Watch Webinar
News

What's New with IntelliMagic Vision for z/OS? 2024.1

January 29, 2024 | This month we've introduced updates to the Subsystem Topology Viewer, new Long-term MSU/MIPS Reporting, updates to ZPARM settings and Average Line Configurations, as well as updates to TCP/IP Communications reports.

Read more

Go to Resources

Book a Demo or Connect With an Expert

Discuss your technical or sales-related questions with our mainframe experts today